The development of a new generation of information technology, such as large data, cloud computing and Internet of things, has pushed the airport to intelligent transformation and upgrading. Under the premise of ensuring information security, air traffic management, airline operation and management, airport operation management and other businesses gradually develop into “cloud data integration and innovative application”.
Power supply system from decentralization to centralization
The trouble of traditional decentralized power supply
As the core system of the infrastructure, the primary concern of the construction department of the Chongqing Jiangbei International Airport’s new terminal is the power supply system of the equipment. Once a power supply failure occurs, it will cause huge losses to the airport. The traditional power supply system uses distributed power supply, that is, one device corresponds to a small UPS. For example, the security channel, check-in, boarding, baggage and other original using decentralized 20-80kVA UPS power supply. Not only is it not convenient to disperse and maintain, but once it fails, it will be difficult for manufacturers to repair and maintain time, which will bring great trouble to airport electromechanical maintenance department. The distributed small UPS is inefficient, and most of the UPS efficiency of the present network is less than 90%, which can not meet the needs of energy saving and emission reduction at present.
Trend of centralized power supply system
The new terminal of the airport construction department, through the investigation of the existing scheme and after full discussion, decided to adopt the centralized power supply, to replace the original decentralized power supply system, the security channel, the original check-in, check-in, baggage and other scattered small capacity UPS power supply area with large capacity UPS centralized power supply. Considering the voltage loss and other problems, the power supply distance of the region can not exceed a certain range, and the UPS centralized power supply capacity is generally above 200kVA. Through the centralized power supply, the power supply efficiency of the system will be greatly improved and the index of energy saving and emission reduction can be realized. At the same time, centralized power supply also solves the problem of decentralized maintenance. The power supply is centralized, and the reliability of the system is higher. The 2N power supply system of power supply structure, redundant double bus system to improve the reliability of the power supply system, the fault of single equipment will not risk the system downtime.

MPS9335 10-1200KVA Without Switch Cabinet Modular Uninterruptible Power Supply

Application IDC(Internet Data Center), computing center, ISP (Internet Service Provider ), Telecom , Finance.
bank and securities , Tax , hospital system , industrial automation , precision equipment, etc.
1. Superior energy saving: Efficiency > 96% at 50%-75% rated load, and > 95% at 25% rated load; Input PF > 0.99,input THDi<3%
2. Easy-to-install: Top or bottom cabling, no need of input cabling cabinet.
3. Easy-to-maintain: Full front access, UPS, failed part can be replaced shortly.
4. Easy-to-modify: The number of batter y cells can be configured flexibly, so the original batteries can be used when modifying the legacy system; moreover, the battery cell can be replaced in time when it fails without interrupting the normal operation of modular uninterruptible power supply.
5. Extra large LCD that can display 13 language (Chinese ,English ,Russian, French ,Spanish and so on).
6. Provide large LCD touch screen (optional).
7. Each modular uninterruptible power supply modules provide 4.5KW charge capacity. equivalent to 10 to 12A.
8. Advanced DSP full digital control technologies realize higher system stability, online capacity expansion and maintenance.
9. Advanced distributed active parallel technology realizes parallel operation of 4 UPS units and online capacity expansion without centralized bypass cabinet.
10. Adaptive to severe power grid environment due to extra wide input voltage and frequency ranges.
11. Intelligent batter y management maintains batter y automatically to prolong the batter y life.
12. The machine system for modular structure, consists of 1 to 10 module’s biggest single module to 30 kw.
13. Modular uninterruptible power supply power module supporting hot swappable, capacity upgrade extremely simple.
14. Super ability for overload and short circuit, ensure the system stability and safety under the limit state of system.