1.Use of AC voltage regulator After using UPS power supply , there is no need to add AC voltage regulator. If it must be added, it should be added to the front level of UPS, that is, the mains power first passes through the AC voltage regulator, then through the ups, and then to the load. 2.Battery balanced charging skills At present, valve regulated lead-acid battery (VRLA) used in many ups power supply is called maintenance free battery from the beginning, which gives users a misunderstanding that it seems that this battery is durable and does not need maintenance at all. Under this kind of misleading, many users have not carried out maintenance and management since they installed the battery. When the battery in UPS power supply meets the following conditions, the battery shall be charged evenly: when the terminal voltage is lower than the specified calibration voltage due to excessive discharge. For 12 V small sealed lead-acid batteries, the discharge calibration voltage is...
Due to the high integration, compact overall structure and large heat dissipation, the hybrid inverter requires high temperature, humidity and dust content in the installation environment. When installing the solar inverter , it must provide a good operating environment for the inverter . The working ambient temperature of the inverter is rated at 40 ℃. If the ambient temperature is higher than 40 ℃ ~ 50 ℃, the rated current must be reduced. Otherwise, the temperature rise of the device will be too high, which will increase the possibility of device damage (especially IGBT power module), and have a great impact on normal and safe operation. If the working environment of the inverter fails to meet the requirements of the inverter on the working environment, it will cause high failure rate of the inverter, affect the long-term, reliable and safe operation, resulting in unnecessary economic losses. Therefore, the following matters should be paid attention to in the...
Manufacturers and users of UPS power supply system have long noticed the matching problem between generators and UPS, especially the harmful effects of current harmonics generated by rectifiers on power supply systems such as voltage regulators of generators and synchronous circuits of UPS. Therefore, the technicians designed the input filter and applied it to UPS, and successfully controlled the current harmonics in UPS application. These filters play a key role in UPS compatibility with generators. In fact, all input filters use capacitors and inductors to absorb the destructive current harmonics at the UPS input. The design of the input filter takes into account the percentage of all possible harmonic distortion inherent in the UPS circuit and at full load. Another benefit of most filters is to increase the input power factor of UPS with load. However, another consequence of the application of input filters is to reduce the overall efficiency of UPS. Most...
评论
发表评论