Daily maintenance of telecom power supply

图片
Under normal operation, high frequency switching power supply equipment has little maintenance workload, mainly dustproof and regular dedusting. Especially in the area where the climate is dry, the dust in the air is more and the dust will be deposited in the machine. When the air is wet, the host control disorder will cause the main engine to be disturbed and the inaccurate alarm will occur. A large amount of dust also causes poor heat dissipation in the device. Generally, every quarter should be thoroughly cleaned. The second is to check whether the connectors and plugging parts are loose or unfastened during the dust removal. Because rectifier can not eliminate instantaneous pulse interference, there is still interference pulse after rectification. In addition to the function of storing DC power, the equivalent capacitance of the battery is directly proportional to the capacity of the storage battery. Therefore, maintenance of battery work is very important, although the battery

Advantages of pure sine wave inverter power supply to important load equipment

图片
Pure sine wave inverter  power supply is specially designed for power plant, substation, communication industry, automation control equipment, solar energy, oil field, wind energy, new energy and so on. It is mainly applied to places where load equipment has high requirements to power quality. Such as power telecontrol, RTU, power line carrier, monitor, program-controlled switchboard, computer room, network, server and accident lighting. If the AC input is broken down, the DC screen or the external battery cabinet prepared by the power system and the telecommunications system will supply a long and uninterrupted power supply through the inverter for the load equipment. If the DC screen is broken down, the inverter overloads or failed, the system will automatically switch to the bypass power supply, which ensures the continuity of the system power supply. The use of pure sine wave inverter power supply to important load equipment in DC power station has the following advantages: 1.Av

The daily maintenance requirements of the power supply system of the telecom room are as follows

图片
1.Check the power equipment regularly. Pay attention to the environment temperature and equipment operation status of the computer room, use the power supply monitoring system to monitor all kinds of operation parameters of the power equipment in real time, and find out the problems in time. 2.Power inspection content. Whether the configuration of the module is reasonable; Whether the charge current limit is correct or not; System AC voltage and current, DC floating charging voltage, load current, battery supplementary electric current, fan running status and lightning protection device status; Whether the running parameters of the monitoring module are correct or not; Whether the temperature compensation is normally used; Whether the module’s average flow is less than 5%; Battery insurance and connection bar temperature rise; Whether the battery is climbing acid, leaking or bulging; The ambient temperature of the machine room, etc. 3.The power supply monitoring system is used to

The definition of low frequency UPS and high frequency UPS

图片
Low frequency UPS  and  high frequency UPS  are distinguished according to the operating frequency of the design circuit of UPS. Low frequency UPS is designed on the basis of traditional analog circuit, composed of thyristor (SCR) rectifier, IGBT inverter, bypass and power frequency step-up isolation transformer. Because of its rectifier and transformer working frequency are 50Hz, so called low frequency UPS. High frequency UPS is usually composed of IGBT high frequency rectifier, battery converter, inverter and bypass. The IGBT can control its opening and closing by adding control to the gate. The switching frequency of the IGBT rectifier is usually from thousands of Hz to tens of kHz, even up to a hundred kHz, far higher than the low frequency UPS, so it is called high frequency UPS. GP9335C 10-800KVA Low Frequency Online UPS ■Use advanced 6th generation DSP and full digital control technologies to realize higher system stability. ■Output power factor is 0.9, carrying capaci

Welcome to visit us at the SNEC PV POWER EXPO 2018

As a power solution expert SOROTEC is dedicated to continuously designing, manufacturing, marketing, and introducing a complete line of UPSs, inverters, and solar power products to the demanding power market. Our newest product Solar Power Inverter: Model  REVO-II ,  SSP3111C ,  SSP3119C  and so on. We sincerely invite you to the SNEC PV POWER EXPO 2018 at the Shanghai New International Expo Centre on May 28-30, 2018. SOROTEC will present innovative green power products in the exhibition. We are looking forward to your coming at  E6-129 130 . Our team is ready to serve you by professional attitude and excellent team spirit. Hall: E6 Booth N.O.: E6 -129 130  Date: May 28-30 2018  Venue: Shanghai New International Expo Centre